Straight FFC Cables
Low-profile, direct PCB-to-PCB or module connections with defined cable length and contact exposure.
XSD Harness provides custom flat flexible cable assemblies for compact electronic and display interconnections. Assemblies are built to customer-defined pitch, conductor count, cable length, contact orientation, connector requirements, routing, and inspection criteria.

A flat flexible cable, or FFC, uses parallel flat conductors laminated within a thin flexible insulation system. Its low-profile construction makes it suitable for compact electrical connections between PCBs, displays, control boards, and electronic modules where space and routing height are limited.
A custom FFC assembly can be defined by pitch, conductor count, overall length, exposed contact length, contact orientation, reinforcement, connector interface, fold pattern, and project-specific electrical or mechanical requirements.
| Product | Construction | Main characteristic | Typical use |
|---|---|---|---|
| FFC | Flat parallel conductors laminated in flexible insulation | Thin, compact, low profile | Board, display, compact electronics |
| Ribbon Cable | Multiple insulated round conductors arranged side by side | Organized multi-wire routing | IDC and general electronic interconnects |
| FPC | Printed copper circuit traces on flexible substrate | Routed circuit patterns | Complex compact electronic circuits |
Customer-specified FPC components can be reviewed for integration. FPC circuit fabrication is separate from FFC assembly capability.
Select a configuration for review against your drawing, mating interface and intended application. Availability is confirmed for the specified construction.
Low-profile, direct PCB-to-PCB or module connections with defined cable length and contact exposure.
Contacts exposed on the same face at both ends, matched to the connector contact positions.
Contacts exposed on opposite faces where the two mating interfaces require a reversed contact orientation.
Specified folds for constrained internal routing, with fold location and bend requirements documented.
Customer-specified connector housings or interface components integrated where the cable system permits.
Selected strain-relief or protective processing, subject to material, tooling and design compatibility.
Same-side contacts are often called Type A or same-face contacts. Opposite-side contacts may be called Type B or reverse-side contacts. Supplier terminology varies.
Side-view schematic · thickness exaggerated for clarity
Contact orientation should always be confirmed by drawing or connector interface rather than relying only on Type A/Type B terminology.
FFC pitch and conductor count depend on cable construction, the mating connector, current requirements, routing constraints and product design. Confirm both against the connector and approved drawing.
Pitch is the center-to-center spacing between adjacent conductors. Conductor count and cable width are related, but width alone does not define the mating interface.
Specify the cable and the finished interface together. Reinforcement thickness, contact exposure and orientation are as important as overall length.
| Parameter | Customization |
|---|---|
| Pitch | According to cable and connector specification |
| Conductor count | Project-specific |
| Cable length | Custom length and defined tolerances |
| Contact orientation | Same-side / opposite-side |
| Exposed contact length | According to drawing |
| Reinforcement | Where required |
| Fold pattern | Straight, Z-fold, angled or project-defined |
| Connector interface | ZIF / FPC connector or specified interface |
| Grounding | Where required |
| Shielding | Only with a compatible specified construction |
| Labels | Custom identification |
| Packaging | Project-specific |
Direct board-to-board or module connections with defined entry and exit positions.
An offset path where the cable changes level or direction inside a compact enclosure.
Routing between offset connector positions, with the fold angle and location specified.
A project-defined path through complex internal packaging, reviewed for cable suitability.
For applications involving repeated motion, provide the expected bend radius, movement pattern and cycle requirement so a suitable cable construction can be evaluated. Fold options require review; heat-formed or permanently formed processes are not assumed.
Cable pitch, conductor count, exposed contact length, reinforcement thickness and contact orientation must match the mating connector specification.
Review ZIF connectors, FPC/FFC board connectors, latch-style connectors, receptacle housings or customer-specified systems by part number. A matching pitch alone does not establish compatibility.
Flat copper conductors, with plating determined by the approved cable specification.
Flexible film construction selected for the required temperature and application.
Stiffener material and thickness at the contact area where required by the interface.
Tin or another specified finish, according to the selected cable and connector system.
Optional shielded construction where project requirements and the approved supply route support it.
Review pitch, count, length, contacts, interface, fold pattern, quantity and inspection requirements.
Confirm the FFC construction, approved source and mating connector.
Prepare the cable to the approved dimensional requirements.
Integrate specified connectors or related components where required.
Apply approved folds, reinforcement, identification or protective features.
Verify dimensions, contact orientation, connector fit and applicable electrical requirements.
XSD’s role is custom assembly and integration. The cable supply route is confirmed per project; this does not imply that all raw FFC is laminated in-house.
The company profile documents wire/cable processing, connector assembly, HDMI soldering, vertical and low-pressure injection molding, electrical testing, dimensional inspection and CCD inspection.
Integration of compatible connector and interface components.
Soldered interconnection where required and compatible with the assembly design.
Molding, reinforcement or dispensing where the FFC design and process permit.
Project-specific checks using available testing and measurement resources.
Overall length, contact exposure, fold positions, reinforcement dimensions and connector position.
Conductor/contact condition, surface damage, fold quality, connector fit and reinforcement.
Continuity or circuit verification and DC resistance, where applicable.
Connector engagement, pull/retention evaluation and bend-related inspection where specified.
Inspection follows the approved quality plan. Signal performance depends on conductor geometry, pitch, grounding, shielding, cable length, connector system and electrical interface. High-speed or impedance requirements need a defined construction and validation method.
Compact board-to-display connections.
Internal controller and PCB interconnections.
Compact device and instrument interconnects, subject to customer qualification.
Thin internal electrical connections.
Space-constrained routing; moving applications require a motion review.
Selected low-profile connections within compact equipment.
Compact module and interface connections.
FFCs are widely used for low-profile connections between LCD/TFT modules, touch interfaces, driver boards and control electronics. For LVDS, eDP, micro-coax or other display-specific interconnects, explore the broader system-level options.
Projects based on drawings, connector specifications, dimensions and approved requirements.
Experience with multiple flat and flexible cable constructions in XSD’s broader manufacturing business.
Customer-specified FFC components integrated into compatible connectorized assemblies and larger wiring systems.
Selected soldering, molding and protective operations matched to the design.
Electrical, dimensional and mechanical inspection resources.
Sample builds, first-article approval and repeat OEM production.
Send the available specifications below. We can identify missing details during the project review.
Provide pitch, conductor count, overall length, contact orientation, exposed contact length and mating connector part numbers. Include the drawing, quantity, fold pattern, reinforcement and inspection requirements. A sample can help resolve remaining details.
FFC uses flat conductors laminated within flexible insulation. Conventional ribbon cable uses individually insulated round conductors arranged side by side. Their contact systems and termination methods differ; the names are not interchangeable.
FFC generally has parallel flat conductors. FPC uses printed circuit traces on a flexible substrate and can include routed circuit patterns. Integrating an FPC component is separate from fabricating the flexible circuit itself.
Both orientations can be reviewed for a custom assembly. Confirm the exposed contact faces on the drawing and provide the mating connector details. Supplier Type A and Type B naming alone is not a sufficient production specification.
Custom length and conductor count can be reviewed against the selected cable construction and connector. The approved drawing establishes dimensions, tolerances and measurement reference points. Available combinations are confirmed during quotation.
Yes, for a confirmed compatible cable and connector system. Pitch, circuit count, contact exposure, reinforced thickness and contact position must match the mating connector drawing. Compatibility is evaluated for the specified part number.
Straight, Z-fold, angled and multi-fold layouts can be reviewed. Supply fold locations, routing space and bend requirements. Repeated-motion applications need a defined movement pattern and cycle requirement before selecting the cable construction.
A sample can support dimensional and interface review. We also need confirmation of hidden requirements such as material, contact finish, circuit assignment and acceptance criteria. Production follows the agreed drawing and specification.
Inspection can include dimensional verification, visual inspection, continuity or circuit verification, and DC resistance where applicable. Connector engagement, retention and bend-related checks are included when specified in the approved quality plan.
Prototype and first-article builds can be reviewed before repeat production. Component availability, quantity, tooling, lead time and acceptance requirements are agreed during quotation; no universal minimum order or lead time is assumed.
Send your pitch, conductor count, contact orientation, length and interface requirements. XSD will review the assembly, routing and inspection needs for your application.