Custom High Voltage Wiring Harnesses

HomeProductsCustom High Voltage Wiring Harnesses

Custom High Voltage
Wiring Harnesses

XSD Harness manufactures build-to-print high-voltage wiring harnesses for electric vehicles, energy storage systems and industrial power applications. Harnesses are produced according to customer-approved drawings, cable and connector specifications, routing requirements and electrical/mechanical inspection criteria.

  • EV & ESS Applications
  • Build-to-Print
  • Custom HV Connectors
  • Prototype to Production

What Is a High Voltage Wiring Harness?

A high-voltage wiring harness connects high-power electrical components within an electric vehicle, battery energy storage system or other high-voltage equipment. Depending on the system architecture, it may connect battery packs, power distribution units, inverters, chargers, motors, DC/DC converters and other power electronics.

Compared with conventional low-voltage harnesses, high-voltage assemblies require greater attention to conductor size, insulation, connector interfaces, shielding, routing, bend radius, temperature, mechanical protection and electrical safety requirements.

Battery Cable Assemblies vs High Voltage Wiring Harnesses

Battery Cable Assemblies High Voltage Wiring Harness
Usually point-to-point power connections Can form a routed HV distribution harness
Battery ↔ inverter / equipment / busbar Battery pack ↔ PDU ↔ inverter ↔ motor / charger
Cable + terminals or lugs Cable + HV connectors + shielding + branches + protection
Focus on conductor size and crimp Focus on system architecture and electrical safety requirements
Often simpler geometry Often multi-branch, routed through a vehicle or equipment
May be low voltage or high voltage Specifically high-voltage applications

Battery Cable Assemblies

Where High Voltage Harnesses Are Used

The harness follows the customer-approved electrical architecture. These simplified connection maps show relationships, not a universal wiring or energy-flow design.

Electric vehicle

Battery PackPDU /
Junction Box
InverterTraction Motor
On-Board ChargerDC/DC ConverterCharging Interface

Energy storage

Battery RackCombiner /
Distribution
PCS / InverterPower System

Illustrative connection topology only; actual branches, charging paths, protection and interlocks are defined by the customer. XSD’s role here is build-to-print manufacturing, not system architecture design.

Custom High Voltage Wiring Harness Types

Battery Pack High Voltage Harnesses

High-voltage connections from battery packs or modules to downstream power equipment.

Battery-to-Inverter Harnesses

Power interconnections between traction or storage batteries and inverters.

Power Distribution Harnesses

HV cable routing between battery systems, junction boxes, PDUs and power electronics.

Motor Power Harnesses

Harnesses connecting inverter output to electric motors or drive systems.

Charging System Harnesses

High-power interconnections associated with charging systems, with the exact design defined by the customer.

DC/DC Converter Harnesses

Specified high-voltage connections for vehicle or equipment power conversion.

Energy Storage HV Harnesses

Power connections within racks, cabinets, PCS/inverter systems and related ESS equipment.

Custom Multi-Branch HV Harnesses

Multi-leg assemblies built to the customer-approved system wiring architecture.

Product photographs illustrate assembly structures. Voltage, current, component identity and application acceptance are established from the approved specification, not appearance alone.

High Voltage Cable Options

The company profile identifies automotive high-voltage cable and EV / EVP new-energy cable categories. The cable used in each harness is selected and approved for that project.

Unshielded High Voltage Cable

For applications where shielding is not required by the system design.

Shielded High Voltage Cable

For specified electromagnetic shielding, cable construction and termination requirements.

Flexible Power Cable

For installation areas requiring routing flexibility and a defined bend radius.

Customer-Specified Automotive HV Cable

Approved customer cable specifications and applicable standards are reviewed before production.

Energy Storage Power Cable

For battery, PCS, inverter and cabinet interconnections.

Selection depends on system voltage, current, conductor cross-section, temperature, shielding, flexibility, bend radius, installation environment and applicable customer or industry requirements.

Cable stock from the company profile
Documented wire and cable manufacturing resources

Orange commonly identifies high-voltage circuits visually. It is not certification: the electrical rating depends on the approved cable construction and applicable specification.

High Voltage Connector & Terminal Options

XSD manufactures around customer-specified connector and terminal systems, subject to sourcing and manufacturing review.

  • Straight HV connectors
  • Right-angle HV connectors
  • Sealed power connectors
  • Shielded HV connectors
  • Ring / lug connections
  • Busbar connections
  • Panel / equipment connections
  • Customer-specified interfaces

High Voltage Interlock Requirements

Where the selected connector and electrical architecture use an HVIL circuit, XSD can manufacture to the customer-approved interlock wiring, connector and pinout specification. This is not a claim of proprietary HVIL system design.

Specified connector and lug interface examples

Key Requirements for a High Voltage Harness Project

Parameter Why it matters
System voltage Determines insulation and component requirements.
Continuous / peak current Influences conductor size and terminal selection.
Cable cross-section Affects current capacity, flexibility and voltage drop.
Connector Defines interface, sealing and termination method.
Shielding Depends on the EMC and system requirements.
Cable length Affects routing and electrical performance.
Bend radius Critical for installation and cable durability.
Temperature Influences cable and component selection.
Environmental exposure Moisture, oil, chemicals, abrasion and vibration.
Routing Controls mechanical protection and clearance.
HVIL As required by the selected electrical architecture.
Inspection / validation Defines final acceptance criteria.

How XSD Manufactures High Voltage Wiring Harnesses

  1. 01

    Technical Review

    Review architecture, voltage/current, cable, connectors, branches, routing, shielding, environment and validation requirements.

  2. 02

    Cable Preparation

    Cut and prepare cable to the approved dimensions and cable construction.

  3. 03

    Shield / Jacket Preparation

    Where applicable, prepare cable layers for the approved shield and connector termination method.

  4. 04

    Terminal / Connector Termination

    Crimp, assemble or otherwise terminate to the component specification and agreed process.

  5. 05

    Harness Assembly

    Route branches and install protective materials, clips, labels and related components.

  6. 06

    Protection

    Apply specified conduit, boots, heat shrink, molding or other protection.

  7. 07

    Inspection & Electrical Testing

    Perform the electrical, dimensional and mechanical checks agreed for the product.

  8. 08

    Final Approval

    Release the assembly according to the approved quality documentation.

Documented general manufacturing resources are shown. The actual cable size, stripping setup, shield preparation, termination tooling and inspection method are confirmed before a specific HV assembly enters production.

High Voltage Terminal Crimping & Connection Quality

Connection quality depends on the correct combination of conductor, terminal geometry, stripping dimensions, crimp tooling and process control. Terminal processing is reviewed against the approved component specification—not one universal crimp setting.

  • Strip dimensions
  • Crimp geometry
  • Conductor position
  • Terminal orientation
  • Pull force
  • Cross-section analysis, where applicable

Maximum HV conductor size is confirmed through stripping capability, crimp force, terminal tooling and inspection review. No unverified mm² processing range is published.

Terminal crimping capabilities

Terminal processing equipment
Terminal cross-section analysis equipment

High Voltage Cable Protection & Routing

Corrugated Conduit

Mechanical protection where specified.

Heat Shrink

Specified cable and termination insulation or support.

Protective Sleeving

Abrasion or routing protection for the selected installation.

Molded / Overmolded Protection

Selected cable and connector interfaces, subject to material and tooling review.

Clips & Fixings

Hold the harness along the approved equipment route.

Identification

HV circuit labels and project-specific identification.

Routing should consider bend radius, mechanical clearance, heat sources, moving components, sharp edges and low-voltage/signal circuits. Cable support and protection follow the installation drawing rather than a generic routing rule.

Protected multi-branch harness structure example
Documented vertical injection molding equipment

The branch photograph illustrates protection and routing structure; it is not evidence that this particular assembly is HV-rated.

Overmolded Wiring Harness

High Voltage Wiring Harness Testing & Inspection

Electrical

  • Continuity / circuit verification
  • DC resistance, where specified
  • Withstand-voltage / hi-pot, where appropriate and confirmed

Crimp / Mechanical

  • Crimp inspection
  • Terminal cross-section analysis
  • Pull-force testing
  • Connector retention

Dimensional

  • Overall lengths
  • Branch dimensions
  • Cable preparation
  • Connector orientation

Environmental

  • Salt spray
  • Bending
  • Aging
  • Customer-defined tests

Method and availability are reviewed; additional validation may need to be arranged.

Wire harness tester
Tensile / pull-force tester
Projection measuring equipment

Test voltage, duration, acceptance criteria and sampling plan are defined by the approved product specification rather than applied as one universal setting.

Insulation-resistance and other HV-specific validation requirements should be identified during project review so that the required test method can be confirmed. The documented general harness tester is not presented as a verified HV dielectric or insulation-resistance system.

DC resistance tester

Testing & inspection capabilities

High Voltage Wiring Harnesses for Electric Vehicles

EV cable assemblies follow the approved vehicle architecture, interfaces and installation requirements. Define the power path, HVIL, shielding and validation requirements before manufacturing review.

  • Battery to PDU
  • Battery to inverter
  • Inverter to traction motor
  • Charging interface
  • On-board charger
  • DC/DC converter
  • Electric compressor / heater
  • Auxiliary HV device

Automotive applications

Energy-storage cabinet application reference

High Voltage Harnesses for Energy Storage Systems

XSD supports high-voltage cable and harness projects for battery and energy-storage systems according to customer-defined cable, connector, routing and inspection requirements.

  • Battery modules
  • Battery racks
  • High-voltage boxes
  • PCS
  • Inverter
  • Power distribution
  • Energy-storage cabinets
  • Auxiliary HV devices

Energy storage applications

High Voltage Harnesses for Industrial Power Equipment

Industrial power connections are reviewed against the equipment’s electrical duty, installation space, environment and maintenance requirements. Specify conductor, termination, protection and acceptance criteria together.

  • Industrial battery systems
  • Inverter systems
  • Power electronics
  • High-power motors
  • Charging equipment
  • Industrial energy systems

Industrial equipment applications

Power and energy-storage equipment application reference

Standards & Customer Specifications

High-voltage harness requirements vary by industry, market and customer. XSD manufactures according to the applicable customer drawing, cable specification, connector requirements and agreed inspection standard. Relevant automotive cable/component standards, OEM requirements and environmental regulations must be identified for the project.

Approval to ISO 6722, ISO 19642, LV216, USCAR or another product standard is not assumed for every assembly. ISO 9001 and IATF 16949 relate to company quality management systems, not universal high-voltage product certification.

Quality systems & certifications

Why Source High Voltage Wiring Harnesses from XSD?

Wire & Cable Manufacturing Background

The company profile documents automotive high-voltage / new-energy cable categories and energy-storage applications.

Build-to-Print Manufacturing

Production follows customer-approved drawings, BOMs, cable and connector specifications and samples.

Integrated Processing

Documented operations include wire preparation, terminal processing, connector assembly, soldering where applicable, molding and inspection.

Prototype to Production

Prototype, pilot and repeat-production stages can be reviewed around the approved assembly configuration.

Automotive Quality Background

ISO 9001 and IATF 16949 quality systems provide company-level context; product qualification remains project-specific.

Project-Specific Inspection

Testing is selected against approved specifications, not unsupported universal performance claims.

From High Voltage Harness Prototype to Production

A controlled prototype stage lets the customer review fit, routing, interfaces and inspection results before repeat manufacture. Approved revisions establish the configuration carried into pilot and production builds.

  1. 1

    Submit HV architecture / drawing

  2. 2

    Electrical & manufacturing review

  3. 3

    Component / tooling review

  4. 4

    Prototype / first article

  5. 5

    Electrical & mechanical inspection

  6. 6

    Customer approval

  7. 7

    Pilot build

  8. 8

    Production

Prototype Wiring Harness

What We Need to Quote Your High Voltage Wiring Harness

Share the information available for technical review. Confirm any confidentiality requirements before uploading unreleased project documents.

Optional preparation checklist — select what you already have.

0 of 24 items ready

Discuss your HV harness requirements






    One file up to 10 MB. Combine multiple documents in a ZIP file.

    Frequently Asked Questions

    What information do you need to quote a high-voltage wiring harness?

    Share the drawing, BOM, voltage, continuous/peak current, cable and connector references, branch dimensions, routing, shielding, operating environment, quantities and test criteria. The checklist above helps identify missing inputs before manufacturing review.

    What cable sizes can XSD process?

    The conductor range is confirmed against cable construction, stripping capability, required crimp force, terminal tooling and inspection method. A universal maximum conductor size is not stated here because the supplied equipment information does not establish one.

    Can XSD manufacture shielded high-voltage harnesses?

    Customer-specified shielded cable systems can be reviewed for assembly. Define the cable, braid or foil structure, shield termination, connector shield, grounding interface and routing requirements. This is not a claim of dedicated in-house shield-braiding machinery.

    Can XSD work with customer-specified HV connectors?

    Yes, subject to component sourcing and manufacturing review. Supply housing, contact, seal and mating-part references, cable compatibility, circuit assignments and assembly instructions. Support for every connector brand or series is not assumed.

    Does XSD support HVIL wiring?

    Where the selected connector and architecture use a High Voltage Interlock Loop, manufacture follows the customer-approved interlock wiring, connector and pinout. This does not imply proprietary HVIL system design.

    Can high-voltage harnesses be waterproof?

    Sealed components and protective processes can be reviewed, but a finished assembly needs a defined ingress requirement and validation method. Sealing depends on the complete connector, seals, jacket and interfaces. See the Waterproof Wiring Harness page.

    What testing is available for high-voltage wiring harnesses?

    Documented resources include circuit verification, DC resistance, crimp cross-section, tensile and dimensional inspection. Hi-pot, insulation resistance and other HV-specific validation methods must be confirmed for the project. Test levels, sampling and acceptance limits follow the approved specification.

    Can XSD manufacture EV battery-to-inverter and energy-storage HV harnesses?

    These applications can be reviewed from approved architecture, cable, connector, routing and inspection requirements. EV or ESS use alone does not establish an assembly voltage/current rating; the complete specification and validation requirements determine suitability.

    Do you provide prototypes before production?

    Prototype and first-article stages can be reviewed before pilot or repeat production. Component availability, tooling and inspection requirements are confirmed for the project. Customer approval records the configuration and revisions to carry into production.

    What standards can XSD manufacture to?

    Applicable customer drawings, cable and connector specifications, OEM requirements and agreed inspection standards are reviewed for the project. ISO 9001 and IATF 16949 describe quality management systems, not universal HV product certification or approval to every automotive cable standard.

    Start Your High Voltage Wiring Harness Project

    Send your drawing, BOM and application requirements. Review the cable, connector, voltage/current, shielding, routing, protection and inspection criteria before production.

    Upload Your HV Harness Drawing & Get a Quote

    We are your trusted leader in manufacturing electrical wire harnesses and custom cables