Custom High Voltage
Wiring Harnesses
XSD Harness manufactures build-to-print high-voltage wiring harnesses for electric vehicles, energy storage systems and industrial power applications. Harnesses are produced according to customer-approved drawings, cable and connector specifications, routing requirements and electrical/mechanical inspection criteria.
- EV & ESS Applications
- Build-to-Print
- Custom HV Connectors
- Prototype to Production
What Is a High Voltage Wiring Harness?
A high-voltage wiring harness connects high-power electrical components within an electric vehicle, battery energy storage system or other high-voltage equipment. Depending on the system architecture, it may connect battery packs, power distribution units, inverters, chargers, motors, DC/DC converters and other power electronics.
Compared with conventional low-voltage harnesses, high-voltage assemblies require greater attention to conductor size, insulation, connector interfaces, shielding, routing, bend radius, temperature, mechanical protection and electrical safety requirements.
Battery Cable Assemblies vs High Voltage Wiring Harnesses
| Battery Cable Assemblies | High Voltage Wiring Harness |
|---|---|
| Usually point-to-point power connections | Can form a routed HV distribution harness |
| Battery ↔ inverter / equipment / busbar | Battery pack ↔ PDU ↔ inverter ↔ motor / charger |
| Cable + terminals or lugs | Cable + HV connectors + shielding + branches + protection |
| Focus on conductor size and crimp | Focus on system architecture and electrical safety requirements |
| Often simpler geometry | Often multi-branch, routed through a vehicle or equipment |
| May be low voltage or high voltage | Specifically high-voltage applications |
Where High Voltage Harnesses Are Used
The harness follows the customer-approved electrical architecture. These simplified connection maps show relationships, not a universal wiring or energy-flow design.
Electric vehicle
Junction BoxInverterTraction Motor
Energy storage
DistributionPCS / InverterPower System
Illustrative connection topology only; actual branches, charging paths, protection and interlocks are defined by the customer. XSD’s role here is build-to-print manufacturing, not system architecture design.
Custom High Voltage Wiring Harness Types
Battery Pack High Voltage Harnesses
High-voltage connections from battery packs or modules to downstream power equipment.
Battery-to-Inverter Harnesses
Power interconnections between traction or storage batteries and inverters.
Power Distribution Harnesses
HV cable routing between battery systems, junction boxes, PDUs and power electronics.
Motor Power Harnesses
Harnesses connecting inverter output to electric motors or drive systems.
Charging System Harnesses
High-power interconnections associated with charging systems, with the exact design defined by the customer.
DC/DC Converter Harnesses
Specified high-voltage connections for vehicle or equipment power conversion.
Energy Storage HV Harnesses
Power connections within racks, cabinets, PCS/inverter systems and related ESS equipment.
Custom Multi-Branch HV Harnesses
Multi-leg assemblies built to the customer-approved system wiring architecture.
Product photographs illustrate assembly structures. Voltage, current, component identity and application acceptance are established from the approved specification, not appearance alone.
Shielding for High Voltage Wiring Harnesses
HV cables near sensitive electronics may require shielding, depending on architecture and EMC requirements. Effectiveness depends on the cable construction, shield termination, connector interface, routing and grounding strategy.
- Braided shielding
- Foil shielding
- Shield termination
- Connector shielding
- Grounding interface
- Routing separation
Assembly of customer-specified shielded cable systems is reviewed for the project. Dedicated in-house braiding machinery, universal EMC performance or a pre-qualified shield structure is not claimed.
Key Requirements for a High Voltage Harness Project
| Parameter | Why it matters |
|---|---|
| System voltage | Determines insulation and component requirements. |
| Continuous / peak current | Influences conductor size and terminal selection. |
| Cable cross-section | Affects current capacity, flexibility and voltage drop. |
| Connector | Defines interface, sealing and termination method. |
| Shielding | Depends on the EMC and system requirements. |
| Cable length | Affects routing and electrical performance. |
| Bend radius | Critical for installation and cable durability. |
| Temperature | Influences cable and component selection. |
| Environmental exposure | Moisture, oil, chemicals, abrasion and vibration. |
| Routing | Controls mechanical protection and clearance. |
| HVIL | As required by the selected electrical architecture. |
| Inspection / validation | Defines final acceptance criteria. |
How XSD Manufactures High Voltage Wiring Harnesses
- 01
Technical Review
Review architecture, voltage/current, cable, connectors, branches, routing, shielding, environment and validation requirements.
- 02
Cable Preparation
Cut and prepare cable to the approved dimensions and cable construction.
- 03
Shield / Jacket Preparation
Where applicable, prepare cable layers for the approved shield and connector termination method.
- 04
Terminal / Connector Termination
Crimp, assemble or otherwise terminate to the component specification and agreed process.
- 05
Harness Assembly
Route branches and install protective materials, clips, labels and related components.
- 06
Protection
Apply specified conduit, boots, heat shrink, molding or other protection.
- 07
Inspection & Electrical Testing
Perform the electrical, dimensional and mechanical checks agreed for the product.
- 08
Final Approval
Release the assembly according to the approved quality documentation.
Documented general manufacturing resources are shown. The actual cable size, stripping setup, shield preparation, termination tooling and inspection method are confirmed before a specific HV assembly enters production.
High Voltage Terminal Crimping & Connection Quality
Connection quality depends on the correct combination of conductor, terminal geometry, stripping dimensions, crimp tooling and process control. Terminal processing is reviewed against the approved component specification—not one universal crimp setting.
- Strip dimensions
- Crimp geometry
- Conductor position
- Terminal orientation
- Pull force
- Cross-section analysis, where applicable
Maximum HV conductor size is confirmed through stripping capability, crimp force, terminal tooling and inspection review. No unverified mm² processing range is published.
High Voltage Cable Protection & Routing
Corrugated Conduit
Mechanical protection where specified.
Heat Shrink
Specified cable and termination insulation or support.
Protective Sleeving
Abrasion or routing protection for the selected installation.
Molded / Overmolded Protection
Selected cable and connector interfaces, subject to material and tooling review.
Clips & Fixings
Hold the harness along the approved equipment route.
Identification
HV circuit labels and project-specific identification.
Routing should consider bend radius, mechanical clearance, heat sources, moving components, sharp edges and low-voltage/signal circuits. Cable support and protection follow the installation drawing rather than a generic routing rule.
The branch photograph illustrates protection and routing structure; it is not evidence that this particular assembly is HV-rated.
High Voltage Wiring Harness Testing & Inspection
Electrical
- Continuity / circuit verification
- DC resistance, where specified
- Withstand-voltage / hi-pot, where appropriate and confirmed
Crimp / Mechanical
- Crimp inspection
- Terminal cross-section analysis
- Pull-force testing
- Connector retention
Dimensional
- Overall lengths
- Branch dimensions
- Cable preparation
- Connector orientation
Environmental
- Salt spray
- Bending
- Aging
- Customer-defined tests
Method and availability are reviewed; additional validation may need to be arranged.
Test voltage, duration, acceptance criteria and sampling plan are defined by the approved product specification rather than applied as one universal setting.
Insulation-resistance and other HV-specific validation requirements should be identified during project review so that the required test method can be confirmed. The documented general harness tester is not presented as a verified HV dielectric or insulation-resistance system.
High Voltage Wiring Harnesses for Electric Vehicles
EV cable assemblies follow the approved vehicle architecture, interfaces and installation requirements. Define the power path, HVIL, shielding and validation requirements before manufacturing review.
- Battery to PDU
- Battery to inverter
- Inverter to traction motor
- Charging interface
- On-board charger
- DC/DC converter
- Electric compressor / heater
- Auxiliary HV device
High Voltage Harnesses for Energy Storage Systems
XSD supports high-voltage cable and harness projects for battery and energy-storage systems according to customer-defined cable, connector, routing and inspection requirements.
- Battery modules
- Battery racks
- High-voltage boxes
- PCS
- Inverter
- Power distribution
- Energy-storage cabinets
- Auxiliary HV devices
High Voltage Harnesses for Industrial Power Equipment
Industrial power connections are reviewed against the equipment’s electrical duty, installation space, environment and maintenance requirements. Specify conductor, termination, protection and acceptance criteria together.
- Industrial battery systems
- Inverter systems
- Power electronics
- High-power motors
- Charging equipment
- Industrial energy systems
Standards & Customer Specifications
High-voltage harness requirements vary by industry, market and customer. XSD manufactures according to the applicable customer drawing, cable specification, connector requirements and agreed inspection standard. Relevant automotive cable/component standards, OEM requirements and environmental regulations must be identified for the project.
Approval to ISO 6722, ISO 19642, LV216, USCAR or another product standard is not assumed for every assembly. ISO 9001 and IATF 16949 relate to company quality management systems, not universal high-voltage product certification.
Why Source High Voltage Wiring Harnesses from XSD?
Wire & Cable Manufacturing Background
The company profile documents automotive high-voltage / new-energy cable categories and energy-storage applications.
Build-to-Print Manufacturing
Production follows customer-approved drawings, BOMs, cable and connector specifications and samples.
Integrated Processing
Documented operations include wire preparation, terminal processing, connector assembly, soldering where applicable, molding and inspection.
Prototype to Production
Prototype, pilot and repeat-production stages can be reviewed around the approved assembly configuration.
Automotive Quality Background
ISO 9001 and IATF 16949 quality systems provide company-level context; product qualification remains project-specific.
Project-Specific Inspection
Testing is selected against approved specifications, not unsupported universal performance claims.
From High Voltage Harness Prototype to Production
A controlled prototype stage lets the customer review fit, routing, interfaces and inspection results before repeat manufacture. Approved revisions establish the configuration carried into pilot and production builds.
- 1
Submit HV architecture / drawing
- 2
Electrical & manufacturing review
- 3
Component / tooling review
- 4
Prototype / first article
- 5
Electrical & mechanical inspection
- 6
Customer approval
- 7
Pilot build
- 8
Production
What We Need to Quote Your High Voltage Wiring Harness
Share the information available for technical review. Confirm any confidentiality requirements before uploading unreleased project documents.
Optional preparation checklist — select what you already have.
0 of 24 items ready
Discuss your HV harness requirements
Frequently Asked Questions
What information do you need to quote a high-voltage wiring harness?
Share the drawing, BOM, voltage, continuous/peak current, cable and connector references, branch dimensions, routing, shielding, operating environment, quantities and test criteria. The checklist above helps identify missing inputs before manufacturing review.
What cable sizes can XSD process?
The conductor range is confirmed against cable construction, stripping capability, required crimp force, terminal tooling and inspection method. A universal maximum conductor size is not stated here because the supplied equipment information does not establish one.
Can XSD manufacture shielded high-voltage harnesses?
Customer-specified shielded cable systems can be reviewed for assembly. Define the cable, braid or foil structure, shield termination, connector shield, grounding interface and routing requirements. This is not a claim of dedicated in-house shield-braiding machinery.
Can XSD work with customer-specified HV connectors?
Yes, subject to component sourcing and manufacturing review. Supply housing, contact, seal and mating-part references, cable compatibility, circuit assignments and assembly instructions. Support for every connector brand or series is not assumed.
Does XSD support HVIL wiring?
Where the selected connector and architecture use a High Voltage Interlock Loop, manufacture follows the customer-approved interlock wiring, connector and pinout. This does not imply proprietary HVIL system design.
Can high-voltage harnesses be waterproof?
Sealed components and protective processes can be reviewed, but a finished assembly needs a defined ingress requirement and validation method. Sealing depends on the complete connector, seals, jacket and interfaces. See the Waterproof Wiring Harness page.
What testing is available for high-voltage wiring harnesses?
Documented resources include circuit verification, DC resistance, crimp cross-section, tensile and dimensional inspection. Hi-pot, insulation resistance and other HV-specific validation methods must be confirmed for the project. Test levels, sampling and acceptance limits follow the approved specification.
Can XSD manufacture EV battery-to-inverter and energy-storage HV harnesses?
These applications can be reviewed from approved architecture, cable, connector, routing and inspection requirements. EV or ESS use alone does not establish an assembly voltage/current rating; the complete specification and validation requirements determine suitability.
Do you provide prototypes before production?
Prototype and first-article stages can be reviewed before pilot or repeat production. Component availability, tooling and inspection requirements are confirmed for the project. Customer approval records the configuration and revisions to carry into production.
What standards can XSD manufacture to?
Applicable customer drawings, cable and connector specifications, OEM requirements and agreed inspection standards are reviewed for the project. ISO 9001 and IATF 16949 describe quality management systems, not universal HV product certification or approval to every automotive cable standard.
Start Your High Voltage Wiring Harness Project
Send your drawing, BOM and application requirements. Review the cable, connector, voltage/current, shielding, routing, protection and inspection criteria before production.